disp4dft 3.2.3 © 1994-2013 by Turku PET Centre

Add dispersion effect to ideal data (ON), or correct a measured data set for dispersion (OFF) [1, 2]. The time constant of the dispersion must be given in the same time units as those that are used in the data file. Program output is written in file in the same format as the input datafile. Usage: disp4dft <ON|OFF> <Datafile> <Dispersion> <Output file> Options: -L Dispersion time and other log information is written as comments in the corrected TAC file -h or --help Print this message and exit --version or --build Print software build information and exit --silent Program works silently, printing only error and warning messages --verbose Program prints more information about what it is doing. Example: disp4dft off us488blood.kbq 2.5 us488blood_disp.kbq References: 1. Iida H, Kanno I, Miura S, Murakami M, Takahashi K, Uemura K. Error analysis of a quantitative cerebral blood flow measurement using H215O autoradiography and positron emission tomography, with respect to the dispersion of the input function. J. Cereb. Blood Flow Metab. 1986; 6:536-545. 2. Oikonen V. Model equations for the dispersion of the input function in bolus infusion PET studies. TPCMOD0003 2002-09-03; http://www.turkupetcentre.net/reports/tpcmod0003.pdf See also: dftunit, fit_winp, fitdelay, dft2svg Keywords: modelling, simulation, input, blood, dispersion This program comes with ABSOLUTELY NO WARRANTY. This is free software, and you are welcome to redistribute it under GNU General Public License.
Last updated 2014-10-22 12:53:48