disp4dft 3.2.3 © 1994-2013 by Turku PET Centre
Add dispersion effect to ideal data (ON), or correct a measured data set
for dispersion (OFF) [1, 2].
The time constant of the dispersion must be given in the same time units as
those that are used in the data file.
Program output is written in file in the same format as the input datafile.
Usage:
disp4dft <ON|OFF> <Datafile> <Dispersion> <Output file>
Options:
-L
Dispersion time and other log information is written as comments in
the corrected TAC file
-h or --help
Print this message and exit
--version or --build
Print software build information and exit
--silent
Program works silently, printing only error and warning messages
--verbose
Program prints more information about what it is doing.
Example:
disp4dft off us488blood.kbq 2.5 us488blood_disp.kbq
References:
1. Iida H, Kanno I, Miura S, Murakami M, Takahashi K, Uemura K. Error
analysis of a quantitative cerebral blood flow measurement using H215O
autoradiography and positron emission tomography, with respect to the
dispersion of the input function. J. Cereb. Blood Flow Metab. 1986;
6:536-545.
2. Oikonen V. Model equations for the dispersion of the input function in
bolus infusion PET studies. TPCMOD0003 2002-09-03;
http://www.turkupetcentre.net/reports/tpcmod0003.pdf
See also:
dftunit,
fit_winp,
fitdelay,
dft2svg
Keywords: modelling, simulation, input, blood, dispersion