imgdv 1.3.5 © 2003-2013 by Turku PET Centre

Estimation of distribution volume (Vt) or distribution volume ratio (DVR) from dynamic PET images in ECAT 6.3, 7.x, NIfTI-1, or Analyze 7.5 format, applying model independent graphical analysis approach of Logan et al [1, 2, 3] for reversible tracer uptake or binding. Simple non-iterative perpendicular line fitting algorithm [4] is applied in determination of the slope of the Logan plot. Parameters: 1) Input file (Plasma or Reference region TAC; times in minutes) 2) Dynamic image file 3) Linear fit start time (0 for automatic determination) 4) Parametric image file Options: -k2=<k2 of reference region> With reference region input it may be necessary to specify also the population average for reference region k2 [2] -Thr=<threshold%> Pixels with AUC less than (threshold/100 x max AUC) are set to zero. Default is 0 % -max=<Max value> Upper limit for Vt or DVR values; by default set pixel-wise to 10x the AUC ratio. -min=<Min value> Lower limit for Vt or DVR values; 0 by default. -F Remove parametric pixel values that are over 4x higher than their closest neighbours. -E=<Fit end time (min)> Never use data after fit end time. -V=<filename> Y axis intercepts times -1 are written as an image in specified file. -N=<filename> Numbers of selected plot data points are written as an image. -h or --help Print this message and exit. -v, --version or --build Print software build information and exit. --silent Program works silently, printing only error and warning messages. --verbose Program prints more information about what it is doing. Example: imgdv ua3818ap.kbq ua3818dy1.v 20 ua3818dv.v The unit of pixel values in the parametric Vt image is (mL plasma)/(mL tissue), and DVR images are unitless. In theory, DVR equals BP+1, and therefore a binding potential image can be computed from DVR image by subtraction of unity, e.g. using program ecatcalc. However, this may lead to a large number of pixels with negative values that may hamper the further statistical or visual analysis. References: 1. Logan J, Fowler JS, Volkow ND, Wolf AP, Dewey SL, Schlyer DJ, MacGregor RR, Hitzemann R, Bendriem B, Gatley SJ, Christman DR. Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11C-methyl]-(-)-cocaine PET studies in human subjects. J Cereb Blood Flow Metab 1990; 10: 740-747. 2. Logan J, Fowler JS, Volkow ND, Wang GJ, Ding YS, Alexoff DL. Distribution volume ratios without blood sampling from graphical analysis of PET data. J Cereb Blood Flow Metab. 1996; 16: 834-840. 3. Logan J. Graphical analysis of PET data applied to reversible and irreversible tracers. Nucl Med Biol 2000; 27:661-670. 4. Varga J & Szabo Z. Modified regression model for the Logan plot. J Cereb Blood Flow Metab 2002; 22:240-244. See also: imgbfbp, imglhdv, ecat2tif, logan Keywords: image, modelling, distribution volume This program comes with ABSOLUTELY NO WARRANTY. This is free software, and you are welcome to redistribute it under GNU General Public License.
Last updated 2014-10-22 12:53:49